8 SAFETY COMPONENT MAINTENANCE
For periodical inspection tests of safety components, see section 10 Periodical
inspections according to EN 81-1 Annex E.
If you replace a safety component, perform the commissioning tests according to
EN 81-1, Annex E. For more information, see section 10 Periodical inspections according to
EN 81-1 Annex E.
The EC-type examination certificate is valid only if the correct type of components and
procedures are used in safety component manufacturing and repair. In order to ensure safety
and conformity, it is essential to use original KONE spare parts only.
NOTE! KONE disclaims any liability resulting from possible safety risks or injuries caused
by the use of other than KONE original spare parts. Do not exceed the recommended
maintenance intervals, unless otherwise instructed by the manufacturer. Local conditions
and application rates may require more frequent maintenance intervals.
NOTE! If the elevator is equipped with safety space arrangement SSA**E devices, read
Appendices A - D before maintaining the elevator.
Figure 9. Example of SSA**E components
CAUTION! After each overspeed governor tripping, check that both safety gear and
overspeed governor are operational before putting the elevator in normal service.
SGI