10.7 Buffer tests
The following sections describe the buffer tests.
10.7.1 Testing the car buffers in pit
Step Action Note
1 Make a car call to the second floor from
the Maintenance Access Pane
l (MAP).
2 If the maintenance access panel (MAP)
is not on the b
ottom floor, close and
lock the MAP.
3 Check that the pit stop switch operates.
1. Open the bottom floor
landing d
oor with the
emergency opening key.
2. Standing on the landing,
press the stop
switch.
3. Close the landing doors and check
that they a
re mechanically locked.
4. Go to the Maintenance Access
Panel (MAP). *
5.
Make a car call from the MAP. The
elevator must not move.
6.
Close and lock the maintenance
access panel (MAP).
Th
e elevator car should be on the
se
c
ond floor
* Reset the pit safety device and Shaft
Access Monitor (SAM, if
applicable)
according to APPENDIX B. Resetting
the safety devices.
4 Open the bottom floor
landing
door with the
emergency opening key.
5
Standing on the landing, press the stop
swit
ch.
1089384.wmf