6.5.3 Elevator behavior in the event of fire according to EN 81-73
The EN 81-73 option, behaviour of an elevator in the even
t of fire, is targeted at elevators
which are not intended for fire fighting or evacuation. If this option is provided, a "No entry"
indication light is installed above the landing call buttons.
A specific pictogram, “Do not use elevator in event of fire”, is installed near the landing call
station.
The “No entry" indication light works in combination with the fire detection device. When the
sensor detects a fire, the elevator returns to the evacuation floor to let passengers out. The
elevator cannot be used after this. At the landing, there is a lighting message that the elevator
is out of service due to fire.
If there is no fire detection sensor, a manual switch at the evacuation floor will allow the fire
fighters to ensure that no persons are trapped in the elevator.
It is the responsibility of the owner to test this function periodically.