KONE NanoSpace™
Owners Manual
85 (196) OM-01.03.086
(B) 2016-01-11
© 2014 KONE Corporation
All rights reserved.
13 Carefully open the machine brakes with
the manual brake opening lever in the
maintenance access panel (MAP).
The elevator car moves down from the
upper limit
switch and the safety circuit
LED (SAFETY INPUT, D49) goes on in
LCEUI. When the LED goes on, close
the brakes.
WARNING! The speed can increase
fast when you open the brake. When
the traction sheave starts to move,
stop it by letting the brakes close
every 0.5 – 1.0 second to prevent the
elevator from accelerating to
overspeed. Release the brake
release lever immediately if the
second speed LED goes on. (D64
DOWN)
NOTE! RDF must be switched on
before the elevator starts to relevel.
14 Switch off the main switch. (220).
Lock and tag.
Step Action Illustration/Note
SGI