BetrHbKRC2FL--USA--Fehler 11.04.00 en
Operating system crashes with exceptional error (blue screen)
Possible causes:
-- Defective memory module(s)
Elimination of fault:
-- Exchange memory module(s)
Controller hangs when loading software components
Possible causes:
-- MFC not correctly connected
-- MFC defective
-- Additional expansion card (e.g. Interbus) interfering with functioning of MFC
-- PCI bus on motherboard faulty
Elimination of fault:
-- Connect MFC correctly
-- Exchange MFC
-- Remove expansion card and run controller up again
-- Exchange PC rack
KUKA HMI does not boot and is aborted with a General Protection fault
Possible causes:
-- Defective files in the software installation
-- Settings in CMOS setup incorrect
-- Defective memory module(s)
Elimination of fault:
-- Reinstall control software
-- Check settings in CMOS setup
-- Exchange memory module(s)