EasyManua.ls Logo

Kuka KR C2 - ESC nodes

Kuka KR C2
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
24 of 86
BetrHbKRC2FL--USA--Fehler 11.04.00 en
3.7 Fault profiles related to a field bus card
3.7.1 Communication via diagnostic interface not possible
Possible causes:
-- Data cable, periphery faulty
-- Diagnostic interface on field bus card defective
Elimination of fault:
-- Take appropriate measures on data cable, periphery
-- Exchange field bus card
3.7.2 Error message “xxxxx I/O driver configuration error
Possible causes:
-- Field bus card incorrectly configured
-- Field bus card cannot be initialized
-- Incorrect configuration of the file IOSYS.INI
Elimination of fault:
-- Check configuration
-- Exchange field bus card
-- Check entries in IOSYS.INI
3.7.3 After inserting the field bus card: no display, controller does not boot (Stop 0)
Possible causes:
-- Field bus card defective
-- Field bus card interferes with MFC function
Elimination of fault:
-- Exchange field bus card
3.7.4 The controller hangs” after initialization of the field bus card
Possible causes:
-- Field bus card defective
Elimination of fault:
-- Exchange field bus card
3.7.5 No external power supply for slave when controller switched off
Possible causes:
-- Interbus filter defective or not correctly connected
-- External power supply input on IBS card defective
Elimination of fault:
-- Exchange Interbus filter (if fiber--optic cable)
-- Exchange Interbus card