133
T1
T2
H4651M2
L4651M2
AM581M2
573987
067242
067553
Virtual configuration (MYHOME_Suite) Physical configuration
Function Parameter / setting
Address of the internal unit from which the lights are controlled. 0-99 SPE=7 M=3
A=1-9, PL=1-9
Type of call:
Virtual configuration (MYHOME_Suite) Physical configuration
Function
Point-to-point SPE=7 M=2
7.2 Floor call control
7.2.1 Addressing
Define the address (two digits) of the internal unit to call by using the control device.
Addressing type Virtual configuration (MYHOME_Suite) Physical configuration
Address of the internal unit 0-99 A=1-9 PL=1-9
To configure the "General" call use MYHOME_Suite virtual configuration
7.3 Control for stair lighting
7.3.1 Addressing
The device takes on the function of the stair lights power button of the internal unit identified by its address (two digits).
8. Sound system control
This mode allows you to control the amplifiers and the sources of the Sound System.
8.1 Addressing
You can manage a single amplifier (point-to-point control), some amplifiers (room
control) and all the amplifiers in the system (general control).
Virtual configuration (MYHOME_Suite) Physical configuration
SPE=8
Addressing type Parameter / setting
Point-to-point Room 0-9 A=0-9
Sound point 0-9 PL=0-9
Room Room 0-9 A=AMB
PF=0-9
General General A=GEN
Special control