17
05/06/2014
LEARN
NETW
DETECT
END_DETECT
1
2
LEARN
NETW
DETECT
END_DETECT
3
4
5
6
7
8
9
82
105
40
0882 91 3579
Wireless movement detector RF ZigBee surface mounting
Size in mm
Each scenario can consist of the timed activation of one or more ON/OFF
and/or Dimmer actuators, depending on the brightness of the room and the presence
(scenario 1), or absence (scenario 2) of people inside the area covered by the IR sensor.
To be used with the ON/OFF radio actuators and dimmers in the «ZigBee radio sys-
tem» range.
Description
Legend
Power supply: No. 2 batteries, AA 1.5V LR06
Duration of the batteries: 2 years
Timing ON: 15 minutes (1)
Minimum brightness threshold for
scenario activation: 1000lux (1)
IR sensor sensitivity: 100% (1)
Operating temperature: 5 – 45 °C
Technology: Radio 2.4 GHz standard ZigBee®
Radio frequency capacity: 100 m free field, 10 m in rooms with
concrete walls
Note (1): the values can be changed using the BMSO4001 and BMSO4003 remote
controls
IR sensor covering area: see drawings on page 2
Technical data
Dimensional data
Front view
1. LED:
- Exhausted battery (flashing slowly)
- presence of people detected inside the area (flashing)
2. Fresnell lens (the IR sensor is underneath)
3. NETWORK LED
4. NETWORK key
5. END DETECT key for the creation of scenario No. 2
6. Closing screw. Remove to open the sensor and replace the batteries
7. DETECT key for the creation of scenario no. 1
8. LEARNING key
9. LEARNING LED
Rear view
MQ00520-c-EN