3476
45
Basic Control Actuator
MQ00077-e-EN 07/06/2014
1.2 Mode
Virtual configuration (MYHOME_Suite) Physical configuration
Function Parameter / setting
Master Actuator Master M=0
Actuator as Slave. Receives a control sent by a Master actuator
with the same address
Slave M=SLA
Pushbutton (ON monostable) ignores Room and General controls Master PUL
OFF Delay = 0
M=PUL
To use the "Actuator as a slave with PUL function", to select the type of load (Actuator,
Lamp, Valve, Differential Reset, Fan, Irrigation, Controlled Outlet, Lock) use MYHOME_
Suite virtual configuration.
1.2.1 ON/OFF control:
Virtual configuration (MYHOME_Suite) Physical configuration
Function Parameter / setting
Cyclic. M=0
ON M=ON
OFF M=OFF
ON with top button, OFF with bottom button. M=O/I
Timed ON 0.5sec M=8
30sec M=7
1min M=1
2min M=2
3min M=3
4min M=4
5min M=5
15min M=6
NOTE:
For timed ON with period 0 to 255 hours and "Timed OFF" control, use MYHOME_Suite virtual
configuration