66
µ
L
N
002602
BMSW1003
Operating mode
Wiring diagram
When in Test mode, by pressing the pushbutton of the actuator it will be possible to enable or disable the associated load.
Maintenance
Do not use acetone, detergents for removing tar, or trichloroethylene.
Maintenance using the following products:
- Hexane (En 60669-1);
- Methylated spirit;
- Soap and water;
- Diluted ammonia;
- Bleach, diluted 10%;
- Glass detergents.
WARNING:
An initial test is required in order to use other special maintenance products.
SCS actuator 4x16A
MQ00313-e-EN 09/06/2014