example measured points, or codes within a job, and the memory space occu-
pied.
☞
Before pressing Format, to format the internal
memory, ensure that all important data is rst
transferred to a computer. Jobs, formats, codel-
ists, conguration les, uploaded languages and
rmware are deleted by formatting.
☞
Despite an automatic defragmentation, the
memory gets fragmented after a while. Please
format the internal memory periodically to main-
tain the instrument performance.
Page 4/4 (Dates)
Field Description
Maint.-End
Date
Displays the end date of the maintenance agreement for the
instrument rmware.
mySec.Rene
wal Date
The date when the instrument must be connected to mySe-
curity in order to renew the security functionality.
Next Service
Date
Displays the date of the next required service check. The
eld can be invisible if turned off by the service reminder.
12.3 Licence Keys
To fully activate rmware contracts, it may be necessary to load a valid licence
key on the instrument. To load a licence key, carry out the procedure
described in the following paragraph.
1. Copy the licence key into the system directory (e.g. D:\system\) on
the USB memory stick.
2. Connect the USB memory stick to the USB interface within the bat-
tery compartment.
3.
Select Tools from the Main Menu.
4.
Select Licence from the Tools Menu.
5. An information message is displayed. To conrm, press Cont. The
licence key is loaded automatically to the instrument.
12.4 Instrument Protection with PIN
The instrument can be protected by a Personal Identication Number. If PIN
protection is activated,the instrument will always prompt for a PIN entry
before starting up. If a wrong PIN has been entered ve times, a Personal
UnblocKing (PUK) code is required.
1.
Select
Tools from the Main Menu.
2.
Select PIN from the Tools Menu.
3. Activate PIN protection by setting Use PIN: On.
Description
Loading a licence key
Description
Activate PIN step-by-
step
Tools 83