ACpower-supplyLEDs
ACDCError(!)DescriptionActionNotes
OnOnOff
Normaloperation.
OffOffOff
Noacpowertothe
serveroraproblem
withtheacpower
source.
1.Checktheacpowertothe
server.
2.Makesurethatthepower
cordisconnectedtoa
functioningpowersource.
3.Restarttheserver.Ifthe
errorremains,checkthe
power-supplyLEDs.
4.Iftheproblemremains,
replacethepower-supply.
Thisisanormal
conditionwhennoac
powerispresent.
OffOffOn
Thepowersupply
hasfailed.
Replacethepowersupply.
OffOnOff
Thepowersupply
hasfailed.
Replacethepowersupply.
OffOnOn
Thepowersupply
hasfailed.
Replacethepowersupply.
OnOffOff
Power-supplynot
fullyseated,faulty
systemboard,or
thepowersupply
hasfailed.
1.Reseatthepowersupply.
2.Followactionsinthe“Power
problems”onpage148.
3.IftheOVERSPECLEDon
thelightpathdiagnosticsis
lit,followtheactionsin“Light
pathdiagnosticsLEDs”on
page124
.
4.IftheOVERSPECLEDon
thelightpathdiagnosticsis
notlit,checktheerrorLEDs
onthesystemboardandthe
IMM2errormessages.Follow
stepsin“Powerproblems”on
page148
and“Solvingpower
problems”onpage156until
theproblemissolved.
Typicallyindicatesa
power-supplyisnot
fullyseated.
OnOffOn
Thepowersupply
hasfailed.
Replacethepowersupply.
OnOnOn
Thepowersupply
hasfailed.
Replacethepowersupply.
DCpower-supplyLEDs
UsethisinformationtoviewDCpower-supplyLEDs.
Thefollowingillustrationshowsthelocationsofthepower-supplyLEDsonthedcpowersupply.
130Systemx3550M4InstallationandServiceGuide