Figure168.Powersupplyremoval
Ifyouareinstructedtoreturnthepowersupply,followallpackaginginstructions,anduseanypackaging
materialsforshippingthataresuppliedtoyou.
Replacingapowersupply
Usethisinformationtoreplaceapowersupply.
Replacingahot-swapacpowersupply
Usethisinformationtoreplaceahot-swapacpowersupply.
Thefollowingnotesdescribethetypeofpowersupplythattheserversupportsandotherinformationthat
youmustconsiderwhenyouinstallapowersupply:
•Beforeyouinstallanadditionalpowersupplyorreplaceapowersupplywithoneofadifferentwattage,
youmayusethePowerConfiguratorutilitytodeterminecurrentsystempowerconsumption.Formore
informationandtodownloadtheutility,gotohttp://www.ibm.com/systems/bladecenter/resources/
powerconfig.html.
•Theservercomeswithonehot-swap12-voltoutputpowersupplythatconnectstopowersupplybay1.
Theinputvoltageis100-127Vacor200-240Vacauto-sensing.
•Powersuppliesintheservermustbewiththesamepowerratingorwattagetoensurethattheserverwill
operatecorrectly.Forexample,youcannotmix550-wattand750-wattpowersuppliesintheserver.
•Powersupply1isthedefault/primarypowersupply.Ifpowersupply1fails,youmustreplacethepower
supplywiththesamewattageimmediately.
•Youcanorderanoptionalpowersupplyforredundancy.
•Thesepowersuppliesaredesignedforparalleloperation.Intheeventofapower-supplyfailure,the
redundantpowersupplycontinuestopowerthesystem.Theserversupportsamaximumoftwo
powersupplies.
Statement5
Chapter6.Removingandreplacingcomponents251