Figure157.ServeRAIDmemorymoduleremoval
Ifyouareinstructedtoreturnthememorymodule,followallpackaginginstructions,anduseanypackaging
materialsforshippingthataresuppliedtoyou.
ReplacingtheServeRAIDadaptermemorymodule
UsethisinformationtoreplacetheServeRAIDadaptermemorymodule.
ToinstalltheServeRAIDadaptermemorymodule,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”
onpage31.
Step2.Turnofftheserverandperipheraldevicesanddisconnectallpowercords.
Step3.Removethecover(see“Removingthecover”onpage189).
Step4.RemovetheServeRAIDSAS/SATAcontroller(see“RemovingaServeRAIDSAS/SATAcontroller
onpage230
).
Step5.AlignthememorymodulewiththeconnectorontheServeRAIDadapterandpushitintothe
connectoruntilitisfirmlyseated.
Figure158.ServeRAIDmemorymoduleinstallation
Chapter6.Removingandreplacingcomponents237