EasyManua.ls Logo

Lenovo System x3550 M4 - Network Connection Problems

Lenovo System x3550 M4
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
Ifanactionstepisprecededby“(Trainedtechnicianonly),thatstepmustbeperformedonlybyatrained
technician.
Gotothesupportwebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,hints,tips,
andnewdevicedriversortosubmitarequestforinformation.
SymptomAction
3.Replacethecomponentslistedinstep2oneatatime,intheordershown,
restartingtheservereachtime:
a.Monitorcable
b.Videoadapter(ifoneisinstalled)
c.Monitor
d.(Trainedtechnicianonly)Systemboard.
Wrongcharactersappearon
thescreen.
1.Ifthewronglanguageisdisplayed,updatetheserverfirmwaretothelatestlevel
(see“Updatingthefirmware”onpage93
)withthecorrectlanguage.
2.Reseatthemonitorcable.
3.Replacethecomponentslistedinstep2oneatatime,intheordershown,
restartingtheservereachtime:
a.Monitorcable
b.Videoadapter(ifoneisinstalled)
c.Monitor
d.(Trainedtechnicianonly)Systemboard.
Networkconnectionproblems
Usethisinformationtosolvenetworkconnectionproblems.
FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
Ifanactionstepisprecededby“(Trainedtechnicianonly),thatstepmustbeperformedonlybyatrained
technician.
Gotothesupportwebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,hints,tips,
andnewdevicedriversortosubmitarequestforinformation.
SymptomAction
Unabletowaketheserver
usingtheWakeonLANfeature.
1.Ifyouareusingthedual-portnetworkadapterandtheserverisconnectedto
thenetworkusingEthernet5connector,checkthesystem-errorlogorIMM2
systemeventlog(see“Eventlogs”onpage133),makesure:
a.Fan3isrunninginstandbymode,ifEmulexdualport10GBase-Tembedded
adapterisinstalled.
b.Theroomtemperatureisnottoohigh(see“Serverfeaturesand
specifications”onpage6).
c.Theairventsarenotblocked.
d.Theairbaffleisinstalledsecurely.
2.Reseatthedual-portnetworkadapter(see“Removingthedual-portnetwork
adapter”onpage238and“Replacingthedual-portnetworkadapter”onpage
239).
3.Turnofftheserveranddisconnectitfromthepowersource;then,wait10
secondsbeforerestartingtheserver.
Chapter4.Troubleshooting147

Table of Contents