I2Cbus
SASandSATAdrives
Ifyouareabletorestarttheserverorifyouneedcomprehensivediagnostics,useDSAPreboot.
Formoreinformationandtodownloadtheutilities,goto
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=SERV-DSA.
RunningtheDSAPrebootdiagnosticprograms
UsethisinformationtoruntheDSAPrebootdiagnosticprograms.
Note:TheDSAmemorytestmighttakeupto30minutestorun.Iftheproblemisnotamemoryproblem,
skipthememorytest.
ToruntheDSAPrebootdiagnosticprograms,completethefollowingsteps:
Step1.Iftheserverisrunning,turnofftheserverandallattacheddevices.
Step2.Turnonallattacheddevices;then,turnontheserver.
Step3.Whentheprompt<F2>Diagnosticsisdisplayed,pressF2.
Note:TheDSAPrebootdiagnosticprogrammightappeartobeunresponsiveforanunusual
lengthoftimewhenyoustarttheprogram.Thisisnormaloperationwhiletheprogramloads.The
loadingprocessmaytakeupto10minutes.
Step4.Optionally,selectQuittoDSAtoexitfromthestand-alonememorydiagnosticprogram.
Note:Afteryouexitfromthestand-alonememorydiagnosticenvironment,youmustrestartthe
servertoaccessthestand-alonememorydiagnosticenvironmentagain.
Step5.Typeguitodisplaythegraphicaluserinterface,ortypecmdtodisplaytheDSAinteractivemenu.
Step6.Followtheinstructionsonthescreentoselectthediagnostictesttorun.
Ifthediagnosticprogramsdonotdetectanyhardwareerrorsbuttheproblemremainsduringnormalserver
operation,asoftwareerrormightbethecause.Ifyoususpectasoftwareproblem,seetheinformation
thatcomeswithyoursoftware.
Asingleproblemmightcausemorethanoneerrormessage.Whenthishappens,correctthecauseofthe
firsterrormessage.Theothererrormessagesusuallywillnotoccurthenexttimeyourunthediagnostic
programs.
Iftheserverstopsduringtestingandyoucannotcontinue,restarttheserverandtryrunningtheDSA
Prebootdiagnosticprogramsagain.Iftheproblemremains,replacethecomponentthatwasbeingtested
whentheserverstopped.
Diagnostictextmessages
Diagnostictextmessagesaredisplayedwhilethetestsarerunning.
Adiagnostictextmessagecontainsoneofthefollowingresults:
Passed:Thetestwascompletedwithoutanyerrors.
Failed:Thetestdetectedanerror.
Aborted:Thetestcouldnotproceedbecauseoftheserverconfiguration.
Additionalinformationconcerningtestfailuresisavailableintheextendeddiagnosticresultsforeachtest.
Chapter4.Troubleshooting137