Step14.Restarttheserver.Thesystembeginsthepower-onself-test(POST).Ifthisdoesnotrecoverthe
primarybank,continuewiththefollowingsteps.
Step15.Removethecover(see“Removingthecover”onpage34).
Step16.ResettheCMOSbyremovingthesystembattery(see“Removingthesystembattery”onpage269).
Step17.Leavethesystembatteryoutoftheserverforapproximately5to15minutes.
Step18.Reinstallthesystembattery(see“Replacingthesystembattery”onpage271).
Step19.Reinstallthecover(see“Replacingthecover”onpage190).
Step20.Reconnectthepowercordandanycablesthatyouremoved.
Step21.Restarttheserver.Thesystembeginsthepower-onself-test(POST).
Step22.Iftheserecoveryeffortsfail,contactyourservicerepresentativeforsupport.
In-bandautomatedbootrecoverymethod
Usethisinformationtorecovertheserverfirmwareandrestoretheserveroperationtotheprimarybank.
Note:UsethismethodiftheBOARDLEDonthelightpathdiagnosticspanelislitandthereisalogentry
orBootingBackupImageisdisplayedonthefirmwaresplashscreen;otherwise,usethein-bandmanual
recoverymethod.
Step1.Boottheservertoanoperatingsystemthatissupportedbythefirmwareupdatepackagethat
youdownloaded.
Step2.Performthefirmwareupdatebyfollowingtheinstructionsthatareinthefirmwareupdatepackage
readmefile.
Step3.Restarttheserver.
Step4.Atthefirmwaresplashscreen,pressF3whenpromptedtorestoretotheprimarybank.The
serverbootsfromtheprimarybank.
Out-of-bandmethod
Usethisinformationtorecovertheserverfirmwareandrestoretheserveroperationtotheprimarybank.
SeetheIMM2documentation(IntegratedManagementModuleIIUser'sGuide)at
http://www.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5086346.
Automatedbootrecovery(ABR)
Whiletheserverisstarting,iftheintegratedmanagementmoduleIIdetectsproblemswiththeserver
firmwareintheprimarybank,theserverautomaticallyswitchestothebackupfirmwarebankandgivesyou
theopportunitytorecoverthefirmwareintheprimarybank.
ForinstructionsforrecoveringtheUEFIfirmware,see“Recoveringtheserverfirmware(UEFIupdatefailure)”
onpage160.Afteryouhaverecoveredthefirmwareintheprimarybank,completethefollowingsteps:
Step1.Restarttheserver.
Step2.WhenthepromptPressF3torestoretoprimaryisdisplayed,pressF3tostarttheserverfrom
theprimarybank.
Nx-bootfailure
Configurationchanges,suchasaddeddevicesoradapterfirmwareupdates,andfirmwareorapplication
codeproblemscancausetheservertofailPOST(thepower-onself-test).
162Systemx3550M4InstallationandServiceGuide