Step5.Reinstalltheharddiskdrivesandfillerpanels(see“Replacingsimple-swapharddiskdrives”on
page202
).
Step6.Installthecover(see“Replacingthecover”onpage190).
Step7.Slidetheserverintotherack.
Step8.Reconnectthepowercordsandanycablesthatyouremoved.
Step9.Turnontheperipheraldevicesandtheserver.
RemovingaUSBembeddedhypervisorflashdevice
UsethisinformationtoremoveaUSBembeddedhypervisorflashdevice.
ToremoveaUSBhypervisorflashdevice,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”
onpage31.
Step2.Turnofftheserverandperipheraldevicesanddisconnectthepowercords.
Step3.Removethecover(see“Removingthecover”onpage189).
Step4.Removetheflashdevice:
Figure186.USBhypervisorflashdeviceremoval
a.UnlocktheretentionlatchontheUSBconnectorbysqueezingthetworetentionclipstoward
eachother.
b.Opentheretentionlatch.
c.Grasptheflashdeviceandpulltoremoveitfromtheconnector.
Ifyouareinstructedtoreturntheflashdevice,followallpackaginginstructions,anduseanypackaging
materialsforshippingthataresuppliedtoyou.
ReplacingaUSBembeddedhypervisorflashdevice
UsethisinformationtoreplaceaUSBembeddedhypervisorflashdevice.
268Systemx3550M4InstallationandServiceGuide