Figure46.ServeRAIDM5110adaptercablerouting
Note:Whenyourestarttheserver,youarepromptedtoimporttheexistingRAIDconfigurationtothe
newServeRAIDadapter.
Ifyouhaveotherdevicestoinstallorremove,dosonow.Otherwise,goto“Completingtheinstallation”
onpage89.
InstallingtheServeRAIDadaptermemorymodule
UsethisinformationtoinstalltheServeRAIDadaptermemorymodule.
ToinstalltheServeRAIDadaptermemorymodule,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”
onpage31.
Step2.Turnofftheserverandperipheraldevicesanddisconnectallpowercords.
Step3.Removethecover(see“Removingthecoveronpage34).
Step4.RemovetheServeRAIDSAS/SATAcontroller(see“RemovingaServeRAIDSAS/SATAcontroller
onpage230
).
Step5.AlignthememorymodulewiththeconnectorontheServeRAIDadapterandpushitintothe
connectoruntilitisfirmlyseated.
60Systemx3550M4InstallationandServiceGuide