Table1.Serverfeaturesandspecifications(continued)
Hot-swapfans:
Onemicroprocessor:4dual-motor
hot-swapfans.
Twomicroprocessors:6
dual-motorhot-swapfans.
Powersupply:
Uptotwohot-swappower
suppliesforredundancysupport
550-wattac
750-wattac
750-wattdc
Note:Powersuppliesintheserver
mustbewiththesamepowerrating
orwattage.
Sixnetworkports(four1Gb
Ethernetportsonthesystem
boardandtwoadditionalports
whentheoptionalDual-Port10Gb
NetworkAdapterisinstalled)
OneSystemManagement
1GbEthernetportonthe
rearconnectedtoasystems
managementnetwork.This
systemmanagementconnectoris
dedicatedtotheIMM2functions.
Oneserialport
RAID5/50(512MBCache)with
optionalFoDRAID6/60and
SEDupgrade
RAID5/50(512MBFlash)with
optionalFoDRAID6/60and
SEDupgrade
RAID5/50(1GBFlash)with
optionalFoDRAID6/60and
SEDupgrade
RAID5/50andSED(Zero
Cache)
AServeRAIDM5120SAS/SATA
adapterthatprovidesRAID0,1,
and10.Optionalupgrade:
RAID5/50(512MBCache)with
optionalFoDRAID6/60and
SEDupgrade
RAID5/50(512MBFlash)with
optionalFoDRAID6/60and
SEDupgrade
RAID5/50(1GBFlash)with
optionalFoDRAID6/60and
SEDupgrade
RAID5/50andSED(Zero
Cache)
Environment:compliantwith
ASHRAEclassA3specifications.
Serveron:
Temperature:
5°Cto40°C(41°Fto104°F)
Altitude:0to950m(3,117ft);
decreasethemaximumsystem
temperatureby1°Cforevery
175-mincreaseinaltitude.
Maximumaltitude:3,050m
(10,000ft),5°Cto28°C(41°Fto
82.4°F)
Humidity:
Non-condensing:-12°Cdew
point(10.4°F)
Relativehumidity:8%to85%
Maximumdewpoint:24°C(75.2°F)
Maximumrateoftemperature
change:
Tapedrives:5°C/hr(41°F/hr)
Harddiskdrives:20°C/hr
(68°F/hr)
Serveroff:
Particulatecontamination:airborne
particulatesandreactivegases
actingaloneorincombination
withotherenvironmentalfactors
suchashumidityortemperature
mightposearisktotheserver.
Forinformationaboutthelimits
forparticulatesandgases,see
“Particulatecontamination”onpage
979
.
Attention:
DesigntoASHRAEClassA3,
ambientof40°C,withrelaxed
support:
Supportcloudlikeworkload
withnoperformance
degradationacceptable
(Turbo-Off)
Undernocircumstance,can
anycombinationofworstcase
workloadandconfiguration
resultinsystemshutdownor
designexposureat40°C
Specificmicroprocessors
supportedenvironment:
MicroprocessorIntelXeon
E5-2690,135W:
Heatoutput:
Approximateheatoutput:
Minimumconfiguration:461Btu
perhour(AC135watts)
Maximumconfiguration:3378Btu
perhour(AC990watts)
Electricalinput:
Sine-waveinput(50-60Hz)
required
Inputvoltagelowrange:
Minimum:100Vac
Maximum:127Vac
Inputvoltagehighrange:
Minimum:200Vac
Maximum:240Vac
Inputkilovolt-amperes(kVA),
approximately:
Minimum:0.14kVA
Maximum:0.993kVA
Notes:
1.Powerconsumptionandheat
outputvarydependingonthe
numberandtypeofoptional
featuresinstalledandthe
power-managementoptional
featuresinuse.