Figure150.ServeRAIDadapterremoval
Note:IfyouhaveinstalledtheoptionalServeRAIDadaptermemorymodule,removeitandkeepit
infutureuse(see“RemovingtheServeRAIDadaptermemorymodule”onpage236).
Step8.PulltheSAS/SATAadapterhorizontallyoutoftheconnectoronthesystemboard.
IfyouareinstructedtoreturntheSAS/SATAadapter,followallpackaginginstructions,anduseany
packagingmaterialsforshippingthataresuppliedtoyou.
ReplacingaServeRAIDSAS/SATAcontroller
UsethisinformationtoreplaceaServeRAIDSAS/SATAcontroller.
TheServeRAIDSAS/SATAcontrollercanbeinstalledinthededicatedconnectoronthesystemboardorPCI
riser-cardslots(see“System-boardinternalconnectors”onpage26
forthelocationoftheconnectors).To
installaSAS/SATAadapter,completethefollowingsteps:
Dependingontheservermodel,theservercomeswithaServeRAIDH1110,aServeRAIDM1115,a
ServeRAIDM5110,oraServeRAID5210SAS/SATAadapterinstalled.
Note:RemovethePCIbracketthatcomewithServeRAIDH1110,ServeRAIDM1115,ServeRAIDM5110
SAS/SATA,oraServeRAID5210adapterbeforeinstallingaSAS/SATAadapterinthededicatedconnector
onthesystemboard.
Attention:
YoucannotinstallServeRAIDH1110whenmicroprocessorIntelXeonE5-2637(FRUpartnumber
49Y8124)isinstalled.
YoucannotinstallServeRAIDM1115or6GbperformanceoptimizedHBAwhenQuadro2000isinstalled.
YoucanreplacetheServeRAIDcontrollerwithanothersupportedServeRAIDcontroller.Foralistof
supportedServeRAIDcontrollers,seehttp://www.lenovo.com/us/en/serverproven/.
Note:Forbrevity,inthisdocumentationtheServeRAIDSAS/SATAcontrollerisoftenreferredtoasthe
SAS/SATAadapterortheServeRAIDadapter.
Chapter6.Removingandreplacingcomponents231