Completethefollowingsteps:
1.VerifythatmatchingProcessorsareinstalledinthecorrectProcessorsocketsaccordingtothe
serviceinformationforthisproduct.
2.CheckIBMsupportsiteforanapplicableservicebulletinorfirmwareupdatethatappliesto
thisProcessorerror.
3.(TrainedServicetechnicianonly)Replacethesystemboard.
I.2018002[I.2018002]ThedevicefoundatBus%Device%Function%couldnotbeconfigured
duetoresourceconstraints.TheVendorIDforthedeviceis%andtheDeviceIDis%.
Explanation:OUT_OF_RESOURCES(PCIOptionROM)
Severity
Info
UserResponse
Completethefollowingsteps:
1.IfthisPCIedeviceand/oranyattachedcableswererecentlyinstalled,moved,servicedor
upgraded,reseatadapterandanyattachedcables.
2.CheckIBMsupportsiteforanyapplicableservicebulletinorUEFIoradapterfirmwareupdate
thatappliestothiserror.NOTE:ItmaybenecessarytodisableunusedoptionROMsfromUEFI
F1setuporASUorusingadaptermanufacturerutilitiessothatadapterfirmwarecanbeupdated.
3.Movecardtoadifferentslot.Ifslotnotavailableorerrorre-occurs,replaceadapter.
4.(TrainedServicetechnicianonly)Ifadapterwasmovedtoadifferentslotanderrordidnot
re-occur,verifythatthisisnotasystemlimitationandthenreplacethesystemboard.Also,if
thisisnottheinitialinstallationandtheerrorpersistsafteradapterreplacement,replacesystem
board.
I.2018003[I.2018003]AbadoptionROMchecksumwasdetectedforthedevicefoundatBus%
Device%Function%.TheVendorIDforthedeviceis%andtheDeviceIDis%.
Explanation:ROMCHECKSUMERROR
Severity
Error
UserResponse
Completethefollowingsteps:
1.IfthisPCIedeviceand/oranyattachedcableswererecentlyinstalled,moved,servicedor
upgraded,reseatadapterandanyattachedcables.
2.Moveadaptertoadifferentsystemslot,ifavailable.
3.CheckIBMsupportsiteforanyapplicableservicebulletinorUEFIoradapterfirmwareupdate
thatappliestothiserror.NOTE:ItmaybenecessarytoconfigureslottoGen1ortouse
specialutilitysoftwaresothatadapterfirmwarecanbeupgraded.Gen1/Gen2settingscanbe
configuredviaF1Setup->SystemSettings->DevicesandI/OPorts->PCIeGen1/Gen2/Gen3
SpeedSelection,ortheASUUtility.
4.Replaceadapter.
796Systemx3550M4InstallationandServiceGuide