Serviceable
Yes
Automaticallynotifysupport
No
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
202-803-000:MemStrTestAborted
UserpressedCtrl-C.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automaticallynotifysupport
No
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
202-901-000:MemStrTestFailed
TestFailed.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.ExecutethestandardDSAmemorydiagnosticstovalidateallmemory.
2.MakesurethattheDSADiagnosticcodeisatthelatestlevel.
3.Turnoffthesystemanddisconnectitfrompower.
4.ReseatthememorycardsandDIMMs.
5.Reconnectthesystemtopowerandturnthesystemon.
938Systemx3550M4InstallationandServiceGuide