EasyManua.ls Logo

Lenovo System x3550 M4 - Page 962

Lenovo System x3550 M4
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Severity
Warning
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.InsertanewCDorDVDintothedriveandwaitfor15secondsforthemediatoberecognized.
Rerunthetest.
2.Checkthedrivecablingforlooseorbrokenconnectionsatbothendsordamagetothecable.
Replacethecableifdamageispresent.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
215-803-000:OpticalDriveTestFailed
OpticalDriveTestFailed.Diskmaybeinusebytheoperatingsystem.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Waitforthesystemactivitytocease
2.Runthetestagain
3.Turnoffandrestartthesystem.
4.Runthetestagain.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
948Systemx3550M4InstallationandServiceGuide

Table of Contents

Related product manuals