EasyManua.ls Logo

Lenovo System x3550 M4 - Page 979

Lenovo System x3550 M4
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
166-907-001:IMMI2CTestFailed
IMMIndicatesfailureinLM75devicebus(BUS6).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
4.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
IBMSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
166-908-001:IMMI2CTestFailed
IMMIndicatesfailureinPCA9567bus(BUS7).
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Performtheactionsmentionedoneatatimeandtrythetestaftereachaction:
1.Turnoffthesystemanddisconnectitfrompower.Waitfor45seconds.Reconnectittopower.
2.MakesurethatDSAandBMC/IMMareatthelatestlevel.
3.Runthetestagain.
AppendixC.DSAdiagnostictestresults965