Technical data
Leuze electronic GmbH + Co. KG BPS 348i 113
13.1.2
BPS with heating
CAUTION
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
Tab.13.9: Electrical equipment
Operating voltage U
B
18…30VDC
Power consumption Max. 17.7W
Structure of the heating Housing heating and separate heating of the optics glass
Warmup time Minimum 30min at +24VDC and an ambient temperature of
-35°C
Minimum conductor cross section Conductor cross section of at least 0.75mm² for the supply
voltage supply line.
Note:
Wiring through of the voltage supply to multiple heating devices
is not permissible.
Standard, M12 ready-made cable not usable (insufficient con-
ductor cross section).
Tab.13.10: Ambient temperature
Ambient temperature (operation) -35°C…+50°C
Ambient temperature (storage) -35°C…+70°C