Functions
Leuze electronic GmbH + Co. KG BPS 348i 30
4.6 Status query of position / speed measurement
Module6 (see chapter 8.4.8 "Module6–Status and control") and module16 (see chapter 8.4.18 "Mod-
ule16–Speed status") in the PROFINET configuration signal status information of the position/speed
measurement.
The following status information can be transmitted to the PROFINET master:
• Status information for position measurement: Input data 0.0…1.7 (see chapter 8.4.8 "Module6–Sta-
tus and control")
• Status information for speed measurement: Input data 0.0…1.5 (see chapter 8.4.18 "Module16–
Speed status")
4.7 Distance measurement to the barcode tape
Within the reading field, the BPS can output the current distance from the read head to the BCB. The dis-
tance from the position label closest to the reference point is output (see chapter 8.4.20 "Module21–dis-
tance to the barcode tape (BCB)").
Output of the distance measurement value:
• In the webConfig tool via the ALIGNMENT function (Quality menu), which is only available in the Ser-
vice operating mode (see chapter 9.3.3 "ALIGNMENT function")
• Via the host interface (input data)