Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG BPS 348i 90
Parameter Rel.
addr.
Data type Value range De-
fault
Unit Explanation
Metr. Inc
h
Error thresh-
old reading
quality
1 unsign
8 bit
10…70 30 ------------- Below this threshold for
reading quality in units of
[%], the BPS generates an
error event.
Reading
quality
smoothing
2 unsign
8 bit
0…100 5 ------------- Insensitivity towards
changes of the quality.
The higher this value is,
the less of an effect a
change has on the reading
quality.
Input data Rel.
addr.
Data type Value range Init
value
Unit Explanation
Metr. Inc
h
Reading quality 0 unsign
8 bit
0…100 0 % % Reading quality in units of
[%] as smoothed value,
dependent on the Smooth-
ing of reading quality pa-
rameter.
8.4.24
Module25–Device status
Module ID:1025 with submodule ID:1
• The module signals various device states via input data.
• The module contains input data (with input data length of 1byte), but no parameters and no output
data.
Input data Rel.
addr.
Data
type
Value range Init
value
Unit Explanation
Metr. Inch
Device status 0 unsign
8 bit
0: Initial value
1: Initialization
10: Standby
11: Service
12: Diagnostics
15: Device is ready
128: Error
129: Warning
0 ------------- This byte represents
the current device sta-
tus.
The following event
messages can be ac-
knowledged via mod-
ule 6 - status and con-
trol (output data bit
0.3):
128: Error
129: Warning
Input data length: 1byte
8.4.25
Module26–Extended status
Module ID:1026 with submodule ID:1
• Via input data, the module signals various pieces of extended status information, such as the current
read direction of the bar code tape.
• The module contains input data (with input data length of 2bytes), but no parameters and no output
data.