Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG BPS 348i 83
Parameter Rel.
addr.
Data
type
Value range De-
fault
Unit Explanation
Metr. Inch
Switching type 0.0 Bit 0…1 0 ------------- Condition for the
Speed limit value3 sig-
nal, which applies to
the switching output
(module4/5) and the
status bit (module16):
0: Exceeded
1: Below minimum
value
Direction selec-
tion
0.1 Bit 0…1 0 ------------- Selection of the limit
value check:
0: Direction indepen-
dent
1: Direction dependent
Speed limit
value3
1…2 unsign
16 bit
0…+20,000 0 mm/s (in/100)/s Limit value is com-
pared to the current
speed.
Speed hystere-
sis3
3…4 unsign
16 bit
0…1,000 100 mm/s (in/100)/s Relative shift of the
switching point to pre-
vent signal bouncing.
Limit value3
range start
5…8 sign
32 bit
-10,000,000
…
+10,000,000
0 mm in/100 The speed limit value
is monitored beginning
at this position.
Limit value3
range end
9…12 sign
32 bit
-10,000,000
…
+10,000,000
0 mm in/100 The speed limit value
is monitored up to this
position.
8.4.16
Module14–Static speed limit value4
Module ID:1014 with submodule ID:1
• The module provides all parameters for the Static speed limit value4 function.
• Further explanations on the Range start and Range end parameters see chapter 8.4.13 "Module11–
Static speed limit value1".
• The module contains parameters (with parameter data length of 13bytes), but no input data and no
output data.
Parameter Rel.
addr.
Data
type
Value range Default Unit Explanation
Metr. Inch
Switching type 0.0 Bit 0…1 0 ------------- Condition for the
Speed limit value4
signal, which applies
to the switching output
(module4/5) and the
status bit (module16):
0: Exceeded
1: Below minimum
value