Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG BPS 348i 87
Input data Rel.
addr.
Data
type
Value
range
Init value Unit Explanation
Metr. Inch
Dynamic speed
limit value active
1.5 Bit 0…1 --- ------------- Signals whether the cur-
rent speed is compared
with the Dynamic speed
limit value:
0: Comparison not active
1: Comparison active
8.4.19
Module20–Free resolution
Module ID:1020 with submodule ID:1
The module is used to implement two parameters that facilitate free scaling of the output values for po-
sition value and speed value.
The free resolution is used if the adjustable resolutions that can be set in module1 or module10 are
not suitable for the application. In modules1 and 10, the Resolution parameter is set to value Free res-
olution. The measurement values are then converted for output with (multiplied by) the parameter val-
ues stored in this module and output.
The module contains parameters (with parameter data length of 4bytes), but no input data and no out-
put data.
Parame-
ter
Rel.
addr.
Data
type
Value
range
Default Unit Explanation
Metr. Inch
Position 0…1 unsign
16 bit
5…50,000 1000 mm/1000 in/100000 Free resolution of the
position value:
Applies for all inter-
faces that selected
the value free resolu-
tion as resolution.
Speed 2…3 unsign
16 bit
5…50,000 1000 (mm/1000)/
s
(in/100000)/s Free resolution of the
speed value.
Applies for all inter-
faces that selected
the value free resolu-
tion as resolution.
8.4.20
Module21–distance to the barcode tape (BCB)
Module ID:1021 with submodule ID:1
The module enables the transmission of the current distance between the BCB and read head (in mm)
to the interface master.
This can be used to check the correct reading distance in the entire system.
Example: A fault in the position value determination is caused by an impermissible reading distance at
this location.
If value 255 is transmitted, a reading distance outside of the permissible reading field was calculated. If
value 0 is transmitted, a valid distance could not be calculated.
The module contains input data (with input data length of 1byte), but no parameters and no output
data.