Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG BPS 348i 85
Parameter Rel.
addr.
Data
type
Value range De-
fault
Unit Explanation
Metr. Inch
Direction selection 0.2 Bit 0…1 --- ------------- Selection of the limit
value check:
0: Direction indepen-
dent
1: Direction depen-
dent
Speed limit value 1…2 unsign
16 bit
0…+20,000 --- mm/s (in/100)/s Limit value is com-
pared to the current
speed.
Hysteresis 3…4 unsign
16 bit
0…1,000 --- mm/s (in/100)/s Relative shift of the
switching point to
prevent signal bounc-
ing.
Limit value range
start
5…8 sign
32 bit
-10,000,000…
+10,000,000
0 mm in/100 The speed limit value
is monitored begin-
ning at this position.
Limit value range
end
9…12 sign
32 bit
-10,000,000…
+10,000,000
0 mm in/100 The speed limit value
is monitored up to
this position.
8.4.18
Module16–Speed status
Module ID:1016 with submodule ID:1
• The module supplies the interface master with various status information for speed measurement via
input data.
• The module contains input data (with input data length of 2bytes), but no parameters and no output
data.
Input data Rel.
addr.
Data
type
Value
range
Init value Unit Explanation
Metr. Inch
Speed measure-
ment error
0.0 Bit 0…1 --- ------------- Signals that no valid
speed could be ascer-
tained:
0: No speed limit value
violation
1: Speed limit value viola-
tion
Speed limit value1
exceeded
0.1 Bit 0…1 --- ------------- Signals that speed limit
value1 has been ex-
ceeded:
0: No limit value violation
1: Value greater than limit
Speed limit value2
exceeded
0.2 Bit 0…1 --- ------------- Signals that speed limit
value2 has been ex-
ceeded:
0: No limit value violation
1: Value greater than limit