Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG BPS 348i 85
Parameter Rel.
addr.
Data
type
Value range De-
fault
Unit Explanation
Metr. Inch
Direction selection 0.2 Bit 0…1 --- ------------- Selection of the limit
value check:
0: Direction indepen-
dent
1: Direction depen-
dent
Speed limit value 1…2 unsign
16 bit
0…+20,000 --- mm/s (in/100)/s Limit value is com-
pared to the current
speed.
Hysteresis 3…4 unsign
16 bit
0…1,000 --- mm/s (in/100)/s Relative shift of the
switching point to
prevent signal bounc-
ing.
Limit value range
start
5…8 sign
32 bit
-10,000,000…
+10,000,000
0 mm in/100 The speed limit value
is monitored begin-
ning at this position.
Limit value range
end
9…12 sign
32 bit
-10,000,000…
+10,000,000
0 mm in/100 The speed limit value
is monitored up to
this position.
8.4.18
Module16–Speed status
Module ID:1016 with submodule ID:1
The module supplies the interface master with various status information for speed measurement via
input data.
The module contains input data (with input data length of 2bytes), but no parameters and no output
data.
Input data Rel.
addr.
Data
type
Value
range
Init value Unit Explanation
Metr. Inch
Speed measure-
ment error
0.0 Bit 0…1 --- ------------- Signals that no valid
speed could be ascer-
tained:
0: No speed limit value
violation
1: Speed limit value viola-
tion
Speed limit value1
exceeded
0.1 Bit 0…1 --- ------------- Signals that speed limit
value1 has been ex-
ceeded:
0: No limit value violation
1: Value greater than limit
Speed limit value2
exceeded
0.2 Bit 0…1 --- ------------- Signals that speed limit
value2 has been ex-
ceeded:
0: No limit value violation
1: Value greater than limit