Starting up the device – Basic configuration
Leuze electronic GmbH + Co. KG BPS 348i 70
Parameter Rel.
addr.
Data
type
Value
range
Default Unit Explanation
Metr. Inch
Output Event for activating the output.
The individual functions are
OR-linked to one another.
2.0 Bit 0…1 0 ------------- Pseudodynamic output:
The control can set and reset
the output on the BPS via
bit0.0 in the output data
0: OFF
1: ON
2.1 Bit 0…1 0 ------------- Device error:
If the BPS detects a device er-
ror, the output is set.
0: OFF
1: ON
2.2 Bit 0…1 0 ------------- Speed limit value1:
If the speed value1 lies out-
side of the configured values,
the output is set.
0: OFF
1: ON
2.3 Bit 0…1 0 ------------- Speed limit value2:
If the speed value2 lies out-
side of the configured values,
the output is set.
0: OFF
1: ON
2.4 Bit 0…1 0 ------------- Speed limit value3:
If the speed value3 lies out-
side of the configured values,
the output is set.
0: OFF
1: ON
2.5 Bit 0…1 0 ------------- Speed limit value4:
If the speed value4 lies out-
side of the configured values,
the output is set.
0: OFF
1: ON