EasyManua.ls Logo

Lexmark X925 7541-03 series - Insert Tray Service Check

Lexmark X925 7541-03 series
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-92 Service Manual
7541-03x
Go Back
Previous
Next
Insert tray service check
7
Check connector J9 on the RIP board for the following
voltages and grounds.
Pins 2, 9, 15, 20, 21 - GND
Pins 10, 16, 17, 18, 23 - +5V
Do the voltages and ground readings approximately
match the table?
Go to step 9. Go to step 8.
8
Replace the RIP board. POR the machine into
Diagnostics mode.
Did this fix the problem?
Problem solved. Go to step 7.
9
Replace the UICC. POR the machine into Diagnostics
mode.
Did this fix the problem?
Problem solved. Contact your
second level
support.
Step Action and questions Yes No
1 Remove the tray and inspect the tray for any damaged
or broken parts that would prevent it from being
installed properly, or move around in the printer. Are
there loose or damaged parts on the tray?
Go to step 2. Go to step 3.
2
Try a different tray. Did this fix the issue? Problem resolved Go to step 3.
3
Check the sensor cables for proper connection to the
sensors and engine controller board. Are they properly
connected?
Go to step 5. Go to step 4.
4
Connect the cables. Did this fix the issue? Problem resolved Go to step 5.
5
Check the size sensors for proper operation. Are they
working properly?
Go to step 7. Go to step 6.
6
Replace the sensors. Did this fix the issue. Problem resolved Got to step 7.
7
Replace the engine controller board. Did this fix the
issue?
Problem solved. Contact your
second level
support.
Step Action and questions Yes No

Table of Contents