3-24 Service Manual
7541-03x
Flash Test
This test causes the file system to write and read data on the flash to test the flash.
Warning: This test destroys all data on the flash because the flash is reformatted at the end of the test.
1. Select Flash Test from DEVICE TESTS From the Diagnostics menu, navigate to:
DEVICE TESTS > Flash Test
A Contents will be lost warning appears.
2. To exit the test immediately and return to DEVICE TESTS, select No and touch Submit. To continue with
the test, select Yes and touch Submit.
When the test starts, a progress bar appears. The test cannot be stopped or canceled once it has begun.
3. Once the test is complete, the power indicator turns on solid and a message appears indicating whether
the test passed or failed. Press Stop (
X) to return to DEVICE TESTS.
Input Tray Tests
This test determines if the printer can feed media from any of the paper input sources. Each of the installed
sources is available within the Input Tray Tests menu.
To run the Input TrayTest:
1. From the Diagnostics menu, touch INPUT TRAY TESTS.
2. Select the input source.
3. Select either Single or Continuous.
Note: If Single is selected, no buttons are active while the input device is feeding. If Continuous is
selected, Stop (
X) can be pressed to cancel the test.
4. At the end of the test, the printer returns to the INPUT TRAY TESTS menu.
PRINTER SETUP
Defaults
This setting is used by the printer to determine whether US or non-US factory defaults should be selected. The
following printer settings have different US and non-US values:
Modification of the printer setting Defaults causes the NVRAM space to be restored to the printer’s factory
settings.
Printer default values US value Non-US value
Paper Sizes setting in the General Settings menu U.S. Metric
Default Paper Size (paper feeding sources which do not have
hardware size sensing capabilities)
Letter A4
Default Envelope Size
(envelope feeding sources which do not have hardware size
sensing capability)
10 Envelope DL Envelope
Fax media size Letter A4
PCL Symbol Set PC-8 PC-850
PPDS Code Page 437 850
Universal Units of Measure Inches Millimeters