Registration sensor (MPF tray) removal
1. Open the right cover door.
2. Pull the cassette guide down.
3. Pinch the tabs (A) that secure the sensor to the cassette guide, releasing the sensor.
4. Disconnect the sensor from the sensor wire harness (B).
Registration sensor actuator removal
Note: The paperfeed unit does not need to be removed from the printer.
1. Open the right cover door.
2. Pull the cassette guide down.
3. Place a flatbed screwdriver under the right side of the actuator, using it as a lever to pull the actuator shaft
out of the cassette guide.