Input Types: Modbus RTU Master
Parameter
Value
Communication port
COM2
Speed
115200
Parity
None
Stop bits
1.0
Timeout
1000
Retries
2
Connectivity
Network interfaces
Value
Ethernet
Static address, IP address: 192.168.0.1, Subnet mask: 255.255.255.0
Wi-Fi
Not configured
PPP
Not configured
Network protocols
Value
DNS
8.8.8.8
FTP Client
Not configured
SMTP
Not configured
NTP
0.pool.ntp.org, 1.pool.ntp.org, it.pool.ntp.org
MQTT
Not configured
Elaboration Parameters
Parameter
Value
Elaboration data delivery time rate (hh:mm:ss)
01:00:00
Elaboration data delivery time rate in alarm condition (hh:mm:ss)
00:10:00
Days of data storage
90
Logics
Name
Measure (reference
value)
Description
Tot Rain last 10 min beyond
limit
RAIN (Last 10 min –
Mobile tot)
Logic is activated when the precipitation detected in
the last 10 minutes is higher than 16 mm
Tot Rain last 60 min beyond
limit
RAIN (Last 60 min –
Mobile tot)
Logic is activated when the precipitation detected in
the last 60 minutes is higher than 16 mm
Wind Inst beyond limit
WindSPEED (Inst)
Logic is activated when the last reading of the wind
speed is higher than 10 m/s
Inst Level beyond limit
LEVEL (Inst)
Logic is activated when the last reading of the level is
higher than 5 m
Increase level last 60 min
beyond limit
LEVEL (Last 60 min –
Mobile max increase)
Logic is activated when the level detected in the last
60 minutes increased by 10 cm
AirTemp Inst below lower
limit
Temperature (Inst)
Logic is activated when the last reading of the air
temperature is lower than 0 °C