EasyManua.ls Logo

LSI LASTEM Alpha-Log - Logic Assigned to an Action

LSI LASTEM Alpha-Log
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alpha-Log User manual
LSI LASTEM SRL
INSTUM_03388
Page 59 / 116
4.1.10.2 Logic assigned to an action
Each logic can be jointed to the following actions:
SMS: when the logic status occurs, Alpha-Log sends one SMS message to up to 5 users. The function
is active only if the data logger works in low consumption mode (§4.1.2) and if a 3G / 4G modem is
connected.
e-mail: when the logic status occurs, Alpha-Log sends the message via e-mail to the specified
addresses. The maximum length of the addresses list cannot exceed 128 characters.
FastMode: when the logic status occurs, Alpha-Log exits from any low-power mode and start sending
data using the value reported in General parameters-> Elaboration data delivery rate in alarm
condition 4.1.7).
MQTT: when the logic status occurs, Alpha-Log sends MQTT messages.
WakeUp: when the logic status occurs, Alpha-Log exits from the low consumption mode and
becomes accessible from the outside, via its network interfaces (§2.2.5).
Inside SMS and e-mail messages it is possible report some related information as: Logic name, Date/Time of
the data generating alarm condition, Site name, Station name and Serial number.
It is possible to attach in the Mail message a file reporting the last measurements.
Fig. 19 Example of Mail action assigned to a logic called “Low Battery”

Table of Contents

Related product manuals