56 The GS550 System
Data Logger
The GS550 includes a data logger that records all significant events including actual sensor values
and a date and time stamp. The data logger memory can hold over 16 000 records, this is equiva-
lent to several days or several years of operation depending on the recording mode selected and
machine use. The data can be extracted using a portable download tool and then transferred to a
personal computer for analysis.
Recording Modes
Adjust the data logger recording mode as required:
1. Press Menu → Next → Next → Next → Enter → Next → Next → Next → Next → Next →
Enter to go to menu 4F1) Data logger mode
2. Use Up and Down to select the data logger recording mode.
3. Automatic modes only: press Next to advance to the adjustment page for the interval (auto-
matic recording mode), variation (automatic variation recording mode), or threshold (automatic
peak recording mode).
4. Press Enter to save any changes.
5. Press Exit three times to return to the operation display or press Next to adjust the data logger
date and time (see below).
Tip: all alerts are recorded by the data logger regardless of the mode selected.
Alarm only. Record alarms only. All the other data logger modes also record alarms.
Figure: An alternative installatio