8. Connect the cables that were removed in Step 3 to the appropriate connector
ports at the front of the replacement Cajun switch.
9. Connect the DC power cable that was removed in Step 2 to the terminal block at
the rear of the replacement Cajun switch.
Note: The ground wire should be connected first.
10. Power up the replacement Cajun switch by closing the circuit breaker for the DC
power cable. To close the circuit breaker, insert the fuse that was removed in
Step 1 by pushing in the fuse while turning it clockwise. The fuse-alarm LED
above the fuse will no longer be lit, and the PWR LED on the front of the unit
will be lit.
11. If not already connected in Step 8, connect a PC or VT100 terminal to the
Console port at the front of the replacement Cajun switch. Refer to the Required
Tools section in this procedure for additional information regarding the
necessary cabling and terminal configuration.
12. Set-up the IP Address on the replacement Cajun switch as follows:
a. Press the Return / Enter key (the name of this key is keyboard dependent) to
display a login prompt.
Response:
The "Login:″ prompt will be displayed.
If the expected response is not received, verify the appropriate cabling is
being used (includes cable and connectors), the cable connection is secure at
each end, and the terminal configuration is set-up correctly.
b. Type and enter the "Supervisor Level" login name:
root
Response:
The "Password:″ prompt will be displayed.
c. Type and enter the "Supervisor Level" password:
root
Response:
Password accepted.
P330-1(super)#
d. Type and enter the following to program the IP Address on the replacement
Cajun switch:
set interface inband 1 10.10.1.245 255.255.255.0
Response:
Management VLAN number set to 1
Interface inband IP address set.
You must reset the device in order for the change to take effect.
e. Type and enter the following to have the IP Address take effect:
reset
Response:
NETWORK PROCEDURES
Procedure 3.14
235-200-150
October 2004
Page 3.14-4 Issue 3.00L