8. Type and enter: u
Response: updating...FORM UPDATED
SWITCHING MODULE (RC_EQIM) 18V1 page displayed.
Cursor at SM attribute.
9. Type and enter: <
Response: 18.0 SM & REMOTE TERMINALS VIEWS page displayed.
10. Type and enter q
Response: RCV-196 COMPLETED
5.11.6.3 Power Down MCTSI Side 0 And Replace Circuit Pack
1. At the MCTSI cabinet, side 0 PCD pack, depress the OFF button.
Response: REPT PWR OFF MCTSI=a-0
Where: a = Switching module number.
2. Warning: An antistatic wrist strap must be worn while handling circuit
packs or system cables to prevent damage to components by static
electricity.
Remove the UM74B/UM74C circuit pack from MCTSI side 0 (per EQL) and
replace with UM74D.
EQL 62-020 TSIU4
EQL 45-017 TSIU4-2
5.11.6.4 Power Up MCTSI Side 0
1. At the MCTSI cabinet, Side 0 PCD pack, depress the ON button.
Response: REPT PWR ON MCTSI=a-0
Where: a = Switching module number.
5.11.6.5 Diagnose MCTSI Side 0
1. At the MCC, either:
type and enter: DGN:MCTSI=a-0,PH=33,RAW,TLP;
or
type and enter: 500,PH=33 (1190,a CMD)
Where: a = Switching module number.
Response: DGN MCTSI=a-0 COMPLETED ATP
5.11.6.6 Unconditionally Restore MCTSI Side 0
1. At the MCC, either:
type and enter: RST:MCTSI=a-0,UCL;
or
type and enter: 300,UCL (1190,a CMD)