Where: a = Switching module number.
Response: RST MCTSI=a-0 COMPLETED
5.11.6.7 Remove MCTSI 1 From Service
1. Switch MCTSI-0 to active side, enter input command 403
2. With MCTSI-0 active, remove (MCTSI) Side 1 from service. At the MCC, either:
type and enter: RMV:MCTSI=a-1;
or
type and enter: 201 (1190,a CMD)
Where: a = Switching module number.
Response: RMV MCTSI=a-1 COMPLETED
5.11.6.8 Update TSICOM 1 CLI
1. Select and prepare terminal for RC/V activities.
2. At the RC/V terminal, type and enter: 18.1U
Response: SWITCHING MODULE (RC_EQIM) 18V1 page displayed.
Cursor at SM attribute.
3. Type and enter switching module number.
Response: System populates remainder of view.
Enter Update, Change, Validate, or Print:
4. Type and enter: c
Response: Change field:
5. Type and enter: TSICOM 1 CLI or field number.
Response: Cursor at TSICOM 1 CLI attribute.
6. Type and enter the appropriate hex value:
DESCRIPTION HEX VALUE
TSIU4 with external clock reference 23
TSIU4-2 with external clock eference 33
Response: Change field:
7. Enter CARRIAGE RETURN
Response: Enter Update, Change, Validate, or Print:
8. Type and enter: u
Response: updating...FORM UPDATED
SWITCHING MODULE (RC_EQIM) 18V1 page displayed.
Cursor at SM attribute.
9. Type and enter: <
Response: 18.0 SM & REMOTE TERMINALS VIEWS page displayed.
ROUTINE MAINTENANCE
Procedure 5.11
235-200-150
January 2003
Page 5.11-10 Issue 3.00