10. Type and enter: q
Response: RCV-196 COMPLETED
5.11.6.9 Power Down MCTSI Side 1 And Replace Circuit Pack
1. At the MCTSI cabinet, side 1 PCD pack, depress the OFF button.
Response: REPT PWR OFF MCTSI=a-1
Where: a = Switching module number.
2. Warning: An antistatic wrist strap must be worn while handling circuit
packs or system cables to prevent damage to components by static
electricity.
Remove the UM74B/UM74C circuit pack from MCTSI side 1 (per EQL) and
replace with UM74D.
EQL 62-116 TSIU4
EQL 53-017 TSIU4-2
5.11.6.10 Power Up MCTSI Side 1
1. At the MCTSI cabinet, side 1 PCD pack, depress the ON button.
Response: REPT PWR ON MCTSI=a-1
Where: a = Switching module number.
5.11.6.11 Diagnose MCTSI Side 1
1. At the MCC, either:
type and enter: DGN:MCTSI=a-1,PH=33,RAW,TLP;
or
type and enter: 501,PH=33 (1190,a CMD)
Where: a = Switching module number.
Response: DGN MCTSI=a-1 COMPLETED ATP
5.11.6.12 Unconditionally Restore MCTSI Side 1
1. At the MCC, either:
type and enter: RST:MCTSI=a-1,UCL;
or
type and enter: 301,UCL (1190,a CMD)
Where: a = Switching module number.
Response: RST MCTSI=a-1 COMPLETED
5.11.7 SAFE STOP POINT
1. This is a Safe Stop Point.
235-200-150
January 2003
ROUTINE MAINTENANCE
Procedure 5.11
Issue 3.00 Page 5.11-11