7.2.1 Post AM Recovery Cleanup
PROCEDURE
1. Inhibit diagnostic sources until disk restore activities are complete. Type and
enter:
INH:DMQ:SRC=ADP;
INH:AUD=SODD,FULL;
2. Clear any active diagnostics from the system. Type and enter:
OP:DMQ;
Response: REQUEST ACTIVE
0 RST MHD 1 BPH=1 EPH=100
SOURCE = ADP PRIORITY = 512
STATUS = ACTIVE
REQUEST WAITING
1 RST MHD 3 BPH=1 EPH=100
SOURCE = MAN PRIORITY = 0
STATUS = WAITING
INHIBIT SOURCES
NONE
OP DMQ COMPLETED
3. If MHD actions are active or waiting, type and enter:
STP:DMQ:MHD=x,zzzzzz;
Where: x = Unit number of MHD
zzzzzz = ACTIVE and/or WAITING as per output message from
previous step.
4. On MCC Page 111, are MHD 2/3 shown as duplexed failed?
If YES, continue with the next step.
If NO, continue with Step 8.
5. At the MCC, write the VTOC file to the MHD being recovered. Type and enter:
EXC:ENVIR:UPROC,FN="/etc/rcvtoc",ARGS=2;
Where: 2 = MHD number to be restored
Response: EXC ENVIR UPROC COMPLETED
vcp: disk copy completed
vcp: disk copy completed
/etc/rcvtoc VTOC READ AND COMPARE
SUCCESSFUL
6. Restore MHD 2. Type and enter:
RST:MHD=2
235-200-150
January 2003
SYSTEM RECOVERY
Procedure 7.2.1
Issue 3.00 Page 7.2.1-1