A2.2.8.6 Corrective Action
If several minutes elapse without recovery or escalation to higher levels of
initialization, see “Analyze AM Initialization Failure,” 235-105-250, 5ESS Switch
System Recovery Manual.
Digits = These digits represent the hardware status of
16-21 the PRM. All digits are active in the
transistor/transistor logic (TTL) high state.
The layout of these digits is as follows:
BIT3210
BIT 3: RST - Indicates that the EAI has gone through a
power-up restart. This bit will remain set
until being read by the maintenance
teletypewriter (MTTY) controller.
BIT 2: RUN - Indicates that the associated administrative
module (AM) is executing main store
instructions. This bit is defined as the
logical AND of NOT stopped (system status
register ([SSR] bit 28) and NOT halted
(SSR bit 17).
POWER
UP
(RST)
CENTER
CONTROL (CC)
UNIT RUN
CC
ACTIVE
EAI-ALL
SEEMS WELL
(ASW)
HARDWARE STATUS BITS (1 of 6)