An off-normal condition on this page will cause the AM or AM PERPH indictor at the
top of the screen to backlight. In this case, the appropriate alarm level (CRITICAL,
MAJOR, MINOR) will also backlight.
2.9.5.3.1 Abbreviations
OOS Out Of Service
ACT Active
MTTY Maintenance Teletypewriter
ROP Receive-Only Printer
UCL Unconditional
2.9.5.3.2 Commands
The 111/112 page provides command to remove, restore, diagnose, and switch the
various units. Also, output commands are available for out-of-service and diagnostic
listings.
CMD RESULT
20X MHD X is removed (RMV: MHD=X)
210 MT 0 is removed (RMV:MT=0)
250 MTTY 0 is removed (RMV:MTTY=0)
260 ROP 0 is removed (RMV:ROP=0)
30X,UCL MHD X is unconditionally restored (RST:MHD=X,UCL)
310,UCL MT 0 is unconditionally restored (RST:MT=0,UCL)
350,UCL MTTY 0 is unconditionally restored (RST:MTTY=0,UCL)
360,UCL ROP 0 is unconditionally restored (RST:ROP=0,UCL)
404 OOS units are listed at ROP (OP:CFGSTAT, OOS)
2.9.5.4 MCC Page 113 - Operations Systems Links
The 113 display page provides a listing of Operations Systems links and their status.
5ESS
®
SWITCH DISTINCTIVE REMOTE MODULE 235-200-150
Feburary 2007
Page 2-44 Issue 3.00O