The RC BACKUP indicator normally shows NORMAL on the right part of the
indicator. If RC Backup fails in the AM, the text NORMAL changes to FAILURE and
the entire indicator backlights.
The next indicator, MTIB, will backlight if an off-normal condition exists on the MTIB
display. Enter command 127 for further details.
In the CUTOVER indicator, the word ACTIVE will backlight if an off-normal condition
exists on the CUTOVER display (cut-over enabled, for example). Further information
can be found on display 197 - CUTOVER.
The indicator BWM AUTOMATION will backlight when the BWM automation process
is halted for any reason.
The indicator SM FILE shows NORMAL (in the right portion of the indicator) while
the system is operating normally. If the UPD:HSCHK audit finds hashsum errors on
any of the SM/SM peripheral, the indicator will backlight and NORMAL changes to
HASHERR. For more information, analyze the last output message from the
UPD:HSCHK command (on the ROP) or request a summary report of the errors via
the UPD:HSCHK,REPT option of the command. The indicator is cleared when the
cause if the disk hashsum error has been corrected and the UPD:HSCHK audit is
re-run.
2.9.5.5.1 Abbreviations
HASHERR Hashsum Error
MTIB Metallic Test Interface Bus
2.9.5.5.2 Commands
Commands are provided to inhibit and allow the call monitor, output the past
15-minute interval history for the call monitor, retire a call monitor alarm or output
ODD WARNING information.
Also, all available displays can be accessed from the 116 display page.
CMD RESULT
601 Call Monitor is inhibited (INH:CALLMON)
701 Call Monitor is allowed (ALW:CALLMON)
801 Call Monitor alarm is retired (RTR:CALLMON,ALARM)
901 Call Monitor history is output (OP:CALLMON)
902 ODD WARNING information is output (OP:ODDWARN,AM)
903 RCLOG WARNING information is output (OP:RCSTAT,AM)
2.9.5.6 MCC Page 124 - DCI/ASM Status
The purpose of the 124 page on the DRM is to provide information about the ASM and
the DCI link. The DCI link for a DRM is a Virtual DCI (VDCI) link over the network
connection to the ASM. The DRM 124 page contains the same information as that on a
3B21 with one exception, only a 3B21 can have a connection to the ASM console port.
Therefore, the bottom box on the 124 page (ASMLNK) which displays the status of the
console port will not display on the 124 page on a DRM. Figure 2-37 shows the 124
page.
235-200-150
Feburary 2007
5ESS
®
SWITCH DISTINCTIVE REMOTE MODULE
Issue 3.00O Page 2-47