OPERATION
Start-Up Procedure
A
DANGER: Avoid possible injury
or
death
from
a runaway machine.
Do
not
start
engine
by
shorting
across starter
teRninals. Machine will
start
in gear and move
if
nonnal
starting
circuitry
is bypassed.
This machine has
two
safety devices which
prevent the engine from starting unless the
variable speed lever
is
in neutral, the steering
wheel is locked In the neutral position, and the
header drive switch is in the
OFF
position.
Under
no
circumstances are these
circuits
to
be deliberately rewired
so
that
the engine can
be started with
controls
out
of
neutral.
Start engine only from operator's seat with
controls
in neutral. NEVER start engine while
standing
on
ground. Machine will start in gear
and move
if
normal starting circuitry
is
bypassed.
Before starting engine, be sure there is plenty
of
ventilation
to
avoid
asphyxiation.
IMPORTANT:
Do
not
tow
machine to start engine.
Damage to hydrostatic drives will
result.
ADJUSTING CONTROLS
1. Engage park brake (A).
2. Move header drive switch (8) to off position.
3.
Move variable speed lever to neutral position
(C).
4. Turn steering wheel until it locks. Adjust
steering wheel
tilt to desired position.
5. Move throttle lever
(0)
to start-up posit
io
n:
0
0
C (32
0
F) and up - Lever fully back.
Below
0° C - Lever fully forward.
CHECKING INSTRUMENTS
The machine gauges and instruments provide
important information about machine operation
and condition.
Familiarize yourself
with
the gauges
and monitor them carefully during start-up
operation. See
"Instruments and Controls
".
NEVER
SHORT
ACROSS
STARTER
TERMINALS
ENGAGE
PARK
BRAKE
ADJUST
CONTROLS
FOR
START-UP
28
)