MAINTENANCE/SERVICE
Form 169469/169470/169471 165 Revision C
7.10.1.3 Charging
CAUTION
Ventilate the area where batteries are
being charged.
Do not charge a frozen battery. Warm to
60
°F (16°C) before charging.
Do not connect or disconnect live
circuits. To prevent sparks, turn off
charger and connect positive cable first.
If charging battery in windrower,
disconnect positive battery cable before
connecting charger cable, then connect
ground cable last, away from battery.
Stop or cut back charging rate if battery
feels hot, or is venting electrolyte.
Battery temperature must not exceed
125
°F (52°C).
Follow all instructions and precautions
furnished by the battery charger
manufacturer. Charge at recommended
rates and times.
7.10.1.4 Boosting
A twelve volt battery can be connected in
parallel (+ to +) with the windrower battery. Use
heavy duty battery cables.
CAUTION
Gas given off by batteries is explosive.
Keep sparks and flames away from
batteries.
Make last connection and first
disconnection at a point furthest away
from the batteries.
Wear protective eye-wear when using a
booster battery.
Be sure everyone is clear of machine
when starting engine. Start engine from
operator's station only.
a. Move platform on right cab-forward side of
machine to open position to allow access to the
battery.
b. Remove red rubber cover (A) from windrower
battery positive terminal.
(continued next page)