Page 49
17.14 SYMPTOM: THE ENGINE STARTER WILL NOT ENGAGE.
CAUSE
a) The controls are not turned 'ON'.
b) The controls are not at the NEUTRAL position.
c) Low battery voltage.
d) Faulty start interlock circuit in the Actuator.
e) Faulty wire, or component, in the starting system.
REMEDY
a) Turn power 'ON' to the control system.
b) Place the control head lever into the NEUTRAL position, and
depress the transfer button.
c) Check the battery voltage. If the voltage is low, charge or
replace the battery.
d) Connect the two (2) start interlock wires (yellow with red
stripe) at the Actuator to the same terminal. If the engine
starts, the Actuator needs to be serviced.
17.15 SYMPTOM: ONE (1) LONG - TWO (2) SHORT TONES FROM
ALL CONTROL STATIONS.
CAUSE
a) Throttle feedback error.
REMEDY
a) Depress the transfer button twice. The Actuator will need to be
serviced at the first opportunity.