THIS PRODUCT IS INACTIVE!
Please contact Mathers Controls for support information.
Page 43
17.3 SYMPTOM: THE LED BLINKS AT ONE (1) STATION WHEN
POWER IS INITIALLY TURNED 'ON' TO THE CONTROLS. CANNOT
TRANSFER TO ANY OTHER STATIONS
CAUSE
a) The transfer button is mis-wired.
b) The transfer button is shorted.
REMEDY
a) Insure that the transfer button is wired per in Section 4.7,
Figure 6. Correct if necessary.
b) Measure the DC voltage across the transfer button. The reading
should be 4.80 to 5.00 volts. If not, replace the transfer button.
17.4 SYMPTOM: THE LED BLINKS WHEN THE TRANSFER BUTTON IS
DEPRESSED, AND CONTINUES TO BLINK AFTER RELEASED (LEVER
IS IN THE NEUTRAL/IDLE POSITION). CANNOT TRANSFER TO
THIS STATION IF ANOTHER STATION WAS PREVIOUSLY IN
CONTROL
CAUSE
The control head potentiometer is not centered.
REMEDY
Replace the control head or install a Control Head Repair Kit.
17.5 SYMPTOM: THE ENGINE RPM VARIES, WITHOUT MOVING THE
CONTROL HEAD LEVER (SYNCHRONIZATION DISABLED).
CAUSE
a) Problem with the governor or carburetor.
b) Erratic command signal.